
( Brand: Hp ), ( Model: 8559A ), ( Part Type: Analyzer )
The HP 8559A Spectrum Analyzer is a high-performance, versatile instrument designed for various applications in the field of electrical engineering, telecommunications, and research. This particular model spans a frequency range of 0.01 Hz to 21 GHz, making it an ideal tool for analyzing signals across an extremely wide spectrum.
The HP 8559A Spectrum Analyzer boasts an impressive resolution bandwidth of 0.001 Hz to 1 MHz, ensuring precise measurement and analysis of signals, even at their most subtle frequencies. It features a dynamic range of 110 dB, enabling it to handle both weak and strong signals with equal accuracy.
The instrument's display is a 12-inch cathode-ray tube (CRT) with a high resolution of 1024 x 1024 pixels. The CRT provides a clear and detailed visual representation of the signal spectrum, with adjustable trace width and color for easy interpretation. The analyzer also offers advanced features such as real-time frequency tracking, time-domain analysis, and fast Fourier transform (FFT) capabilities.
The HP 8559A Spectrum Analyzer is equipped with a built-in signal source, allowing for direct input and analysis of signals. It also supports various external modulation options, such as amplitude, frequency, and phase, enabling more complex signal analysis. The instrument is also compatible with a wide range of probes and accessories, further expanding its capabilities.
The HP 8559A Spectrum Analyzer is housed in a robust, thermally controlled enclosure, ensuring optimal performance and stability in various environmental conditions. The analyzer is also easy to use, with a user-friendly interface and comprehensive software for data analysis and reporting.
In summary, the HP 8559A Spectrum Analyzer is a powerful and versatile tool for signal analysis, offering exceptional performance, wide frequency range, and a range of advanced features. Its robust construction and user-friendly interface make it an ideal choice for engineers, researchers, and technicians in various fields.
Pros of buying a HP 8559A Spectrum Analyzer:1. Wide frequency range: The HP 8559A covers a frequency range of 0.01 Hz to 21 GHz, making it suitable for a wide variety of applications, from radio frequency (RF) and microwave engineering to aerospace and defense.
2. High accuracy: The HP 8559A is known for its high accuracy and precision, with a measurement uncertainty of 0.05 dB and a resolution bandwidth of 0.01 Hz.
3. Versatility: The HP 8559A can be used for a variety of measurements, including power level, frequency, phase, and modulation.
4. Durability: The HP 8559A is a robust and durable instrument, built to withstand harsh environments and heavy use.
Cons of buying a HP 8559A Spectrum Analyzer:1. High cost: The HP 8559A is a high-end instrument, and its price reflects its advanced features and capabilities. It may be out of reach for some budgets.
2. Complexity: The HP 8559A is a complex instrument with many settings and options, which can be overwhelming for beginners or users who are not familiar with spectrum analyzers.
3. Size and weight: The HP 8559A is a large and heavy instrument, which may be difficult to transport or use in a portable setting.
Conclusion:The HP 8559A Spectrum Analyzer is a powerful and versatile instrument with a wide frequency range and high accuracy. However, its high cost and complexity may be prohibitive for some users. If you have the budget and the need for a high-performance spectrum analyzer, the HP 8559A could be a good choice. But if you are looking for a more affordable or user-friendly option, there are other spectrum analyzers on the market that may better suit your needs.
Recommendation:If you are looking for a high-end spectrum analyzer with a wide frequency range and high accuracy, the HP 8559A is a good option to consider. However, if you have a limited budget or are looking for a more user-friendly option, you may want to explore other options on the market, such as the Rigol DS1054Z or the Anritsu MS2760A. It is important to carefully consider your needs and budget before making a purchase.
01 to 18 ghz maximum cumulative error v for 8 division deflection on CRT blanking, aux BBC output provides pen down unblinking signal at low impedance 15 pen lift blanking 10 k impedance 21 all frequency bands calibrated display range log 70 db with scale 1 scale linear 8 divisions linear Lin amplitude scale amplitude accuracy calibrator-10 DBMS RMS input attenuation dc or ac hz from reference level log, attenuation band width switching variation 3 MHz 30 khz into 50 35 khz reference level 10 steps and a 12 vernier calibrated adjustment 112 60 accuracy 10 -80 DBMS. Resolution band width accuracy 3-db points are except for 3 MHz band width : 30 selectivity 60-db 3-db ratio 15:1 spectral stability fundamental mixing, bands of frequency span accuracy displayed separation spectral resolution band width sleight delectable band width s from 1 khz to in a 1, sequence. Noise level DBMS 1 khz frequency response db max. 5 db3 MHz to 1 khz db for 10 DBMS signal, input attenuation average noise level frequency range ghz avg alternate if available at.
Sale for Hp spectrum analyzer model 8559A frequency range. Db per 10 step to 60 db. 01 to 21ghz shipping USA 120 agent Hp 8559A spectrum analyzer plug-in range 0. 01 to 3 ghz: 1 MHz db 60 db, level is about 10 DBMS into with a signal displayed at the reference.
3 of frequency to 21 ghz: 5 MHz ghz in six delectable ranges frequency entire spectrum selected bandier division 10 khz 200 a 1, 2, sequence zero span analyzer functions as manually tuned receiver frequency accuracy tuning accuracy 0. 3, 10 db input attenuation output characteristics vertical output, aux ABC output detected video from. 1 second noise side bands 70 db down, 30 khz from of cw signal with resolution band width and full video range-111 to input damage levels total power 20 DBMS 100 m, 1 peak pulse power 50 DBMS 1 10 ms width , 0.
0 db display fidelity log incremental accuracy output is controlled by settings of resolution Be, input attend, and reference level horizontal output, aux debunk 5 k provides horizontal sweep from 5 v to for full 10 division CRT deflection db frequency responses table above includes attenuate mixer flatness, mixing mode gain variation band, with 1or db attenuation input attenuate 0 70 db, delectable in steps step RMS attenuation 30 DBMS 1 watt, 7. Band width and frequency span are independently variable or may be coupled for optimum display when control markers aligned. Amplitude accuracy db max. 4 MHz if output, aux CBC output provides a signal which is proportional to the RF input.
3 alternate irregular if at ghz, 6-9 ghz sweep is automatically adjusted to maintain absolute amplitude calibration for any combination of frequency span, resolution band width , and video filter band width calibrated times 2 SEC 10 sec in a 1, 2, 5 sequence except 2, accuracy with typical accuracy manual sweep spectrum analyzer may be swept manually either direction front panel control signal input characteristics input impedance 50 nominal precision type-n female connector input stereotypical duty cycle 30 db attenuation gain compression db vernier over 70 range linear 3 reference level spurious responses second harmonic distortion below 40 DBMS signal attenuation third order inter modulation two 30 signals MHz separated by 50 khz attenuation residual responses 90 attenuation no present db, 10 -100 DBMS: residual FM 1 p-p.